The PS75 series modular, true online double conversion transformer-less design with 3-Level IGBT Inverter topology UPS ranging from 75kVA to 1200kVA is designed to protect any critical load for medium and large data center achieving maximum availability. The PS75 series feature the latest technology of DSP Microprocessor based control, using IGBT devices, high switching frequency PWM and PFC input control & Input Phase Sequence Correction, which guarantees ultra high efficiency of 97.1% and reliability.
SPECIFICATION OF RACK | ||||||
---|---|---|---|---|---|---|
Model | P575R6MU42 | P575R8MU42 | P575R12MU42 | P575R16MU42 | ||
Rating (kVA) Configurable | 450 | 600 | 900 | 1200 | ||
Dimension WxDxH (mm) | 900 x 1000 x 2000 (S) 1200 x 1000 x 2000 (F) |
1200 x 1000 x 2000 | 1800 x 1000 x 2000 | 2000 x 1000 x 2000 | ||
Weight (Kg) | 344 | 387 | 618 | 700 | ||
Bypass | Feature | Hot-Swappable Inbuilt Static Bypass Module & Inbuilt Maintenance Bypass Switch | ||||
Frequency | 50 / 60 Hz ± 10% | |||||
Voltage | ± 20% | |||||
Overload | 135% Overload Continuous; > 1000% Overload for 100 ms | |||||
Monitoring | Touch Screen Display | |||||
Nos. of Module | 75kVA x 06 | 75kVA x 08 | 75kVA x 12 | 75kVA x 16 | ||
Switches & Connections | Connections - Rectifier Input / Output / Bypass Input / Battery & Switches - Input, Bypass, Output & Maintenance Bypass | |||||
SPECIFICATION OF MODULE | ||||||
MODULE | P575M3375 | |||||
Dimension WxDxH (mm) | 442 x 628 x 172. 4U | |||||
Weight (Kg) Each 75kVA | 45 Kg | |||||
INPUT | ||||||
Nominal Voltage | 380V / 400V / 415V AC (3Ph+N+PE) | |||||
Operating Voltage Range | 132V ~ 276V AC (Phase to Neutral) for 100% Load & 132V ~ 176V AC (Phase to Neutral) for 100% Load | |||||
Operating Frequency Range | 50/60Hz ± 10% | |||||
Power Factor | ≥ 0.99 | |||||
Harmonic Distortion (THDi) | ≤ 3% | |||||
Generator Input / Walking | Support | |||||
OUTPUT | ||||||
Output Voltage | 380V / 400V / 415V AC (3Ph+N+PE) | |||||
Voltage Regulation | ± 1% | |||||
Power Factor | 1.0 (Unity) | |||||
Frequency | Auto Sensing 50 / 60 Hz ± 3Hz Sync Mode (Configurable: ± 10/60 Hz ± 0.1 Hz (Free Running / Self Clocked Mode) | |||||
Crest Factor | 3:1 | |||||
Harmonic Distortion (THDv) | ≤ 1% | |||||
Over Load | ≤ 110% for 60 min, ≤ 125 % for 10 min, ≤ 150% for 1 min, > 150% for 200 ms | |||||
Slew Rate | 1 Hz/s | |||||
Phase Displacement Angle | 120° ± 1° (At 100% Balanced Load) & 120° ± 2° (At 100% Balanced Load) | |||||
Transient Response & Response Time | 0% to 90 % step load < ± 5% < 10 ms (Asynchronized Mode) | |||||
Efficiency | 97.1% Dual Conversion Mode, 98.4% EPS Mode, 99.0% ECO Mode | |||||
BATTERY | ||||||
Battery Voltage | ± 240V DC Nominal (32 – 44 Nos. Configurable) | |||||
Charging Current | 15A | |||||
SYSTEM FEATURE | ||||||
Self Diagnostics | During Power ON and Software Control | |||||
EPO | UPS Shut down | |||||
Transfer Time | Zero | |||||
Alarm Protections | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Load, DC Bus Under / Over Voltage and Battery low | |||||
Data Logging & Statistical Data | 16,384 events on LCD: Over temp, DC Bus Fan Fail, Fuse Fail, Overload, Short circuit, Device Fail, Inverter Fail, Rectifier Fail, Bypass fail, etc | |||||
Display | Touch Screen LCD & LED Indication | |||||
ENVIRONMENTAL | ||||||
Temperature | Operating 0°C; Storage: -25°C ~ 70°C | |||||
Humidity / Altitude | 0 ~ 95% RH Non-condensing / < 1500 M (above sea level without derating. Derating 1% for each additional 100m | |||||
Noise | < 65dBA | |||||
STANDARDS | ||||||
Quality | ISO 9001, ISO 14001, ISO 27001, ISO 50001, RoHS | |||||
Safety | IEC/EN62040-1 | |||||
EMC / Performance | Complying to CE, IEC/EN62040-2, IEC/EN62040-3 | |||||
COMMUNICATION INTERFACE | ||||||
Standard | Rack, RS232, RS485, Dry Contact | |||||
Optional | BMS/ Rs485/ LBS / SNMP / ModBus / Dry Contact / Parallel, Dry contact, Relay Card, Battery temperature sensor | |||||
Monitoring Software | NetAgent Utility v5.8 / Muser 4000 / Power Manager |