This UPS system uses True Online Double-Conversion (VFI) and DSP technology to deliver high performance and pure sine wave output. It supports rack/tower configuration, has a wide input voltage range (100–300V AC), and a unity power factor (1.0). Key features include 3-stage battery charging, frequency conversion, ECO mode, EPO, parallel expansion (up to 4 units), and configurable battery setup (16–20 units). It also supports fan speed control, automatic bypass, cold/soft start, and is generator compatible.
Model | MP1106LB16 | MPII1106L16 | MP1110L16 | |
---|---|---|---|---|
Phase | Single Phase with Ground | |||
Capacity | 6KVA/6KW | 10KVA/10KW | ||
Parallel Capability | 4 | |||
INPUT | ||||
Nominal Voltage | 220/ 230/ 240 V AC (1P+N+PE) | |||
Voltage Range | 100V ~ 300V AC | |||
Frequency | 40~70Hz | |||
Power Factor | ≥ 0.99 | |||
THDi | ≤3% | |||
OUTPUT | ||||
Output Voltage | 220/ 230/ 240 V AC (1P+N+PE) | |||
AC Voltage Regulation | ± 1% | |||
Frequency Range (Synchronized Range) | 50/60Hz +/- 1% ~ 10% (Configurable) | |||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||
Current Crest Ratio | 3:1 | |||
Harmonic Distortion | ≤ 1% | |||
Transfer time | Zero | |||
Overload | < 110% for 60 min, 110% ~ 125% for 10 min, 125% ~ 150% for 1 min, >= 150% 200 msec | |||
Efficiency | ≥ 94.0% Online Double Conversion ; ≥ 99.0% ECO Mode | |||
SYSTEM FEATURES | ||||
Alarms / Protections | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low | |||
Indications | Input Voltage/frequency, Output Voltage/frequency, Load Percentage, Battery Voltage, Temperature, Remaining Battery Backup Time, Load VA/W, Load and Battery Barograph | |||
BATTERY | ||||
Battery Type | 12V / 9Ah | SMF VRLA / Lithium Battery Compatible | ||
Battery Voltage / Numbers | ± 96V / 16Nos. | ± 96V ~ ± 120V DC / 16 ~ 20 pcs (Adjustable) | ||
Charging Current | 1A/2A (Configurable) | 4A 9standard) & 10A (optional)Max. | ||
Typical Recharge Time | 4-6 Hrs recover > 90% capacity | 6-8 Hrs recover > 90% capacity | ||
PHYSICAL | ||||
Dimension, W x D x H (mm) | 443 x 625 x 177 (4U) | 443 x 625 x 88 (2U) | 443 x 625 x 88 (2U) | |
Net Weight (Kgs) | 48 | 16 | 18 | |
ENVIRONMENT | ||||
Temperature | Operating: 0 ~ 50 deg C & Storage: -15 deg C ~ 60 deg C | |||
Humidity / Altitude | 0~95% RH (Non-condensing) / 1500M | |||
Noise Level | Less than 50dbA @ 1 Meter | |||
STANDARDS | ||||
Quality | ISO 9001, ISO 14001, ISO 45001, ISO 27001, ISO 50001, RoHS | |||
Safety | IEC/EN62040-1 | |||
EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE | |||
COMMUNICATION INTERFACE | ||||
Standard | Smart RS232, USB, EPO, Parallel Port | |||
Optional | SNMP / RS485 / Dry Contact / IoT | |||
Monitoring Software | BPE Cyber / Muser 5000 |