True Online Double Conversion with DSP
Controlled Sine Wave
IGBT, Both Inverter & Rectifier
Optimization Battery Group, The Quantity of
Battery: 16/18/20 Nos.
High Input Power Factor 0.99
High Output Power Factor 1.0
Wide Input Voltage Range: 120~280V AC
Wide Input Frequency Range (50Hz:45~55Hz/60Hz: 54~66Hz)
Rear Panel
1. Fan
2. Input Switch
3. Output Switch
4. Maintenance Switch
5. Terminal
6. Com Port
7. USB Port
8. Parallel Port
9. EPO
10. Intelligent Slot / SNMP(Optional)
MODEL | MFP1105L16 | MFP1106L16 | MFP1110L16 | |
Capacity (kVA / kW) | 05 / 05 | 06 / 06 | 10 / 10 | |
INPUT | ||||
Nominal Voltage | 220V / 230V / 240V AC (L+N+PE) | |||
Operating Voltage Range | 110V~300V AC Load Dependent | |||
Operating Frequency Range | 50 / 60 Hz ± 10% (Auto Sensing) | |||
Power Factor | 0.99 | |||
Bypass | Voltage | ± 20% (Configurable) | ||
Frequency | ± 10% (Configurable) | |||
ECO Range | Same as the Bypass, can be configured | |||
Generator Input | Compatible | |||
OUTPUT | ||||
Rated Voltage | 220V / 230V / 240V AC L+N+PE (Configurable) | |||
Power Factor | 0.8 (Standard) 0.9 / 1.0 (Optional) | |||
Voltage Regulation | ±1% | |||
Frequency | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode | |||
Crest Factor | 3:1 | |||
Overload | ≤ 125% for 10 Min, ≤ 150% for 30 Sec, ≥ 150% for 200ms | |||
Harmonic Distortion (THDv) | ≤1 | |||
Efficiency | 94.0% Dual Conversion Mode, 99.0% ECO Mode | |||
BATTERY | ||||
Battery Voltage | 192V DC / 216V & 240V DC (Configurable) | |||
Typical Recharge Time | 4-5 Hours to 90% of full Capacity | |||
Charge Current | 6A | 10A | ||
SYSTEM FEATURES | ||||
IP Protection | IP 20 | |||
Transfer Time | Zero | |||
EPO / ECO / CVCF | Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable | |||
Alarm / Protection | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low | |||
LED Display | Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault | |||
LCD Display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Bargraph | |||
INVIRONMENTAL | ||||
Temperature | Operating: 0~50°C*, Storage: -15ºC ~ 60ºC | |||
Humidity / Altitude | 0~95% RH Non-condensing / <1500 M | |||
Noise | ≤ 45dBA | |||
PHYSICAL | ||||
Dimension WxDxH (mm) | 192x465x345 | 192x540x345 | ||
Net Weight (Kg) | 12 (L), 58 (B) | 14 (L), 68(B) | ||
STANDARDS | ||||
Quality | ISO 9000, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS | |||
Safety | IEC/EN62040-1 | |||
EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE | |||
COMMUNICATION INTERFACE | ||||
Standard | RS-232 | |||
Optional | SNMP / ModBus / Dry Contact / USB / RS-485 | |||
Monitoring Software | NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 |