True Online Double Conversion UPS with DSP-controlled pure sine wave output, IGBT-based inverter and rectifier, low input harmonic distortion (≤3%), high input/output power factors (0.99/1.0), wide voltage (208–480V) and frequency range, battery optimization (16–20 units), generator compatibility, ECO mode, self-testing at startup, optional parallel operation up to 4 units, static bypass, cold start, and flexible 3/1 & 1/1 operation.
MODEL | MFII3110L16 |
---|---|
Capacity | 10 kVA |
INPUT | |
Nominal Voltage | 380V / 400V / 415V AC (3P+N+PE) |
Operating Voltage Range | 320V~480V AC Load Dependent |
Operating Frequency Range | 50 / 60 Hz ± 10% (Auto Sensing) |
Power Factor | ≥0.99 |
Bypass Voltage | -40% ~ +15% (Configurable) |
Bypass Frequency | ±5% (Configurable) |
ECO Range | Same as the Bypass, can be configured |
Generator Input | Compatible |
OUTPUT | |
Rated Voltage | 220V / 230V / 240V AC L+N+PE (Configurable) |
Power Factor | 1.0 |
Voltage Regulation | ±1% |
Frequency | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.5 Hz Battery Mode |
Crest Factor | 3:1 |
Overload | ≤105% for Continuous, ≤125% for 10 Min, ≤150% for 60 Sec, ≥150% for 200ms |
Harmonic Distortion (THDv) | ≤1% |
Efficiency | 94.0% Dual Conversion Mode, 99.0% ECO Mode |
BATTERY | |
Battery Voltage | 192V DC / 216V & 240V DC (Configurable) |
Typical Recharge Time | 4-5 Hours to 90% of full Capacity |
Charge Current | 14A |
SYSTEM FEATURES | |
IP Protection | IP20 |
Transfer Time | Zero |
EPO / ECO / CVCF | Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable |
Alarm / Protection | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low |
LED Display | Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault |
LCD Display | Input Voltage, Input Frequency, Output Voltage, Frequency, Current, Load Percentage, Battery Voltage, Charging/Discharging/Current Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Barograph |
ENVIRONMENTAL | |
Temperature | Operating: 0~50°C*, Storage: -15°C ~ 60°C |
Humidity / Altitude | 0~95% RH Non-condensing / <1500 M |
Noise | <55dBA |
PHYSICAL | |
Dimension WxDxH (mm) | 250 x 580 x 655 |
Net Weight (Kg) | 37 |
STANDARDS | |
Quality | ISO 90001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS, FCC |
Safety | IEC/EN62040-1; Conformity to IEC / EN |
EMC / Performance | IEC/EN62040-2 ; IEC/EN62040-3, Complying to CE, Compliance to UL |
COMMUNICATION INTERFACE | |
Standard | RS-232 |
Optional | SNMP / ModBus / Dry Contact / USB / RS-485 / SMS Alert Card |
Monitoring Software | NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 |
*Conditions apply. Specifications are subject to change without prior notice. |