Double conversion Online design, which makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, low distortion and without power fluctuation interference, providing the load with more comprehensive protection.
Pure online with static bypass technology, provides a strong protection against overload and fault. Built-in manual maintenance bypass,further improves the reliability of continuous operation.
Double conversion Online design, which makes the output a pure sine wave source with tracking frequency, phase-lock and voltage regulation, low distortion and
without power fluctuation interference, p r o v i d i n g t h e l o a d w i t h m o r e comprehensive protection.
Pure online with static bypass technology, provides a strong protection against overload and fault. Built-in manual maintenance bypass, further improves the reliability of continuous operation.
Built-in isolation transformer, strong antiinterference ability, provides more comprehensive protection.
The range of AC input voltage is 380V ± 20%, thereby it reduces the battery using frequency and greatly extending the battery life. Wide input frequency range & ensure all type of generator compatible
Self-diagnostic function before start-up, avoid the risks failure. The multi-protections such as overload, short circuit, over temperature, battery under voltage, battery over-charge and so on greatly ensure the system stability and reliability. Built-in static electronic bypass switch. when UPS fail, it can transfer to bypass mode and continue to provide power to load.
Adoption of IGBT inverter & Charger saves energy & coupled with an isolation transformer, enhances the reliability and load adaptability.
Same Unit can be directly connected in parallel, increasing the scalability of the system. Non-fixed master-slave relationship: Among several UPS in parallel, the unit
startup first is master UPS , the others are slave UPS. The master and slave can be exchanged. If the inverter of one UPS fail, the UPS will automatically cut off the output, then the load will be powered by remained UPS.
Communication with computer can be realized by RS-232 with corresponding monitoring software. The various parameters can be shown on the communication interface.
The UPS with remote network management capability can provide real-time data for communication and management through a variety of network management systems.
The outside cabinet is designed only with locks without any screws and all PCBAs are coated for anti-moisture, anti-electric leakage, anti-dust and anti-corrosion. Its robust design is suitable for harsh environment with high temperature, high humidity, dense dust, salt, or fierce vibration.
|
Technical Specifications of DS II Series 10~40kVA | ||||||||||||
MODEL | DSII3110L16 | DSII3115L16 | DSII3120L16 | DSII3125L16 | DSII3130L16 | DS3120L30 | DSII3120L30 | DSII3130L30 | DSII3140L30 | ||||
Capacity (kVA) | 10 | 15 | 20 | 25 | 30 | 20 | 30 | 40 | |||||
INPUT | |||||||||||||
Voltage Range | 380V / 400V / 415V AC ± 20% (3Ph+N+PE) | ||||||||||||
Frequency Range | 50 Hz / 60 Hz ±10% ( Auto Sensing) | ||||||||||||
OUTPUT | |||||||||||||
Voltage Range | 220V / 230V / 240V AC (± 1%) | ||||||||||||
Frequency Range | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode | ||||||||||||
Power Factor | 0.8 Standard, (0.9 Optional) | ||||||||||||
Crest Factor | 3:1 | ||||||||||||
Efficiency | 94.0% Dual Conversion Mode, 99.0% ECO Mode | ||||||||||||
THDv | ≤1% | ||||||||||||
Overload | ≤ 125% for 10 Min, ≤ 150% for 1 Min, > 150% for 300 ms | ||||||||||||
BATTERY | |||||||||||||
Battery voltage | 192V DC | 360V DC | |||||||||||
Charging Current (Amp.) | 12 Amp. | 10 ~ 40 Amp. | |||||||||||
SYSTEM FEATURES | |||||||||||||
Transfer Time | Zero | ||||||||||||
Display | LED | Utility Status, Inverter, Bypass, Battery Status, UPS Abnormal, Overload and Fault | |||||||||||
LCD | I/O Voltage, Frequency, Battery Voltage, Load, Temperature and fault | ||||||||||||
Alarm / Protection | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low | ||||||||||||
Parallel Card (Optional) | Yes | Yes | Yes | Yes | Yes | No | Yes | Yes | Yes | ||||
ENVIRONMENT | |||||||||||||
Temperature | Operating: 0~50°C*, Storage: -15ºC ~ 60ºC | ||||||||||||
Humidity / Altitude | 0~95% RH Non-condensing / <1500 M | ||||||||||||
Noise | ≤50dBA | ≤55dBA | |||||||||||
PHYSICAL | |||||||||||||
Dimension WxDxH (mm) | 310x590x870 | 400x815x1100 | 300x815x830 | 405x656x817 | 432x821x1159 | ||||||||
Net Weight (Kg) | 115 | 125 | 201 | 230 | 277 | 150 | 145 | 193 | 278 | ||||
STANDARDS | |||||||||||||
Quality | ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS | ||||||||||||
Safety | IEC/EN62040-1 | ||||||||||||
EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE | ||||||||||||
COMMUNICATION INTERFACE | |||||||||||||
Standard | RS-232 | ||||||||||||
Optional | SNMP / ModBus / Dry Contact / USB / RS-485 | ||||||||||||
Monitoring Software | NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 |