The UPS features true online double conversion with DSP control, supporting both 50Hz and 60Hz frequencies. It is compatible with generators and includes an ECO mode for energy savings. The system performs self-testing during startup, supports parallel operation of up to four units, and offers static bypass, auto start, and cold start functions.
Rear Panel
1. Fan
2. Input Switch
3. Output Switch
4. Maintenance Switch
5. Terminal
6. Com Port
7. USB Port
8. Parallel Port
9. EPO
10. Intelligent Slot / SNMP(Optional)
| MODEL | MFP1105L16 | MFP1106L16 | MFP1110L16 | |
| Capacity (kVA / kW) | 05 / 05 | 06 / 06 | 10 / 10 | |
| INPUT | ||||
| Nominal Voltage | 220V / 230V / 240V AC (L+N+PE) | |||
| Operating Voltage Range | 110V~300V AC Load Dependent | |||
| Operating Frequency Range | 50 / 60 Hz ± 10% (Auto Sensing) | |||
| Power Factor | 0.99 | |||
| Bypass | Voltage | ± 20% (Configurable) | ||
| Frequency | ± 10% (Configurable) | |||
| ECO Range | Same as the Bypass, can be configured | |||
| Generator Input | Compatible | |||
| OUTPUT | ||||
| Rated Voltage | 220V / 230V / 240V AC L+N+PE (Configurable) | |||
| Power Factor | 0.8 (Standard) 0.9 / 1.0 (Optional) | |||
| Voltage Regulation | ±1% | |||
| Frequency | Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode | |||
| Crest Factor | 3:1 | |||
| Overload | ≤ 125% for 10 Min, ≤ 150% for 30 Sec, ≥ 150% for 200ms | |||
| Harmonic Distortion (THDv) | ≤1 | |||
| Efficiency | 94.0% Dual Conversion Mode, 99.0% ECO Mode | |||
| BATTERY | ||||
| Battery Voltage | 192V DC / 216V & 240V DC (Configurable) | |||
| Typical Recharge Time | 4-5 Hours to 90% of full Capacity | |||
| Charge Current | 6A | 10A | ||
| SYSTEM FEATURES | ||||
| IP Protection | IP 20 | |||
| Transfer Time | Zero | |||
| EPO / ECO / CVCF | Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable | |||
| Alarm / Protection | Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low | |||
| LED Display | Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault | |||
| LCD Display | Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage, Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Bargraph | |||
| INVIRONMENTAL | ||||
| Temperature | Operating: 0~50°C*, Storage: -15ºC ~ 60ºC | |||
| Humidity / Altitude | 0~95% RH Non-condensing / <1500 M | |||
| Noise | ≤ 45dBA | |||
| PHYSICAL | ||||
| Dimension WxDxH (mm) | 192x465x345 | 192x540x345 | ||
| Net Weight (Kg) | 12 (L), 58 (B) | 14 (L), 68(B) | ||
| STANDARDS | ||||
| Quality | ISO 9000, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS | |||
| Safety | IEC/EN62040-1 | |||
| EMC / Performance | IEC/EN62040-2; IEC/EN62040-3, Complying to CE | |||
| COMMUNICATION INTERFACE | ||||
| Standard | RS-232 | |||
| Optional | SNMP / ModBus / Dry Contact / USB / RS-485 | |||
| Monitoring Software | NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000 | |||