MPP Series 1~3kVA

This UPS uses True Online Double-Conversion (VFI-SS-111) with DSP and IGBT technology for high performance and pure sine wave output. It supports a wide input voltage range (100V–300V AC) with input power factor ≥0.99. It features 3-stage battery charging, hot-swappable batteries, and a user-friendly LCD.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online Double-Conversion Technology (VFI-SS-111)
  • DSP Technology Guarantees High Performance
  • Pure Sine Wave Output
  • IGBT Based both Rectifier & Inverter
  • Wide Input Volatge Range (100V~300V AC)
  • Input Power Factor Correction ≥0.99
  • 3-Stage Charging for Optimized Battery Performance
  • Rack mount / Tower Convertible Design
  • Output Power Factor unity (1.0, kVA = kW)
  • Hot-swappable Battery Design
  • User Friendly LCD for Monitoring
  • Supports Frequency Conversion Mode
  • ECO mode operation for energy saving
  • Emergency power off function (EPO)
  • Fan Speed Regulation as per Load
  • Automatic Static Bypass Switch
  • Inbuilt Cold Start & Soft Start Feature
  • Auto Restart Function
  • Generator Input Compatible
  • IoT Compatible with wifi/Bluetooth Monitoring

Internal Battery Model MPP1101B2 MPP1102B6 MPP1103B6
External Battery Model MPP1101L2 MPP1102L6 MPP1103L6
PHASE Single Phase with Ground
CAPACITY 1000VA / 1000W 2000VA / 2000W 3000VA / 3000W
INPUT
Nominal Voltage 208/220/230/240VAC
Input Voltage Range 100-300 VAC at 50% load
160-300 VAC at 100% load
Frequency Range 40Hz ~ 70 Hz
Power Factor ≥ 0.99 @ Nominal Voltage (100% load)
OUTPUT
Output Voltage 208/220/230/240VAC
Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 47~53 Hz or 57~63 Hz
Frequency Range (Batt. Mode) 50Hz/60Hz ± 0.1 Hz
Current Crest Ratio 3:1
Harmonic Distortion ≤ 1% THD (Linear Load)
Transfer
Time
AC Mode to Battery Mode Zero
Bypass to Inverter 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
Efficiency (AC to AC) 92.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
Internal
Battery
Model
Battery Type 12 V / 9 AH
Numbers 2
6 6
Typical Recharge Time 4-6 Hrs recover >90% capacity
Charging Current 1.0 A
Charging Voltage 27.4VDC ± 1V 82.1 VDC ± 1V
External
Battery
Model
Battery Type SMF VRLA / Lithium Battery Compatible
Numbers 3 6
Charging Current (max.) 1.0A/2.0A/4.0A/6.0 A
Charging Voltage 41.0VDC ± 1V 82.1 VDC ± 1
STATUS INDICATION
LCD Panel UPS status, Load level, Battery level Input/Output voltage, Discharge timer and Fault conditions
Alarm / Protection Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current, Over Load, DC BUS Under / Over Voltage and Battery low
PHYSICAL
Internal
Battery Model
Dimension, D x W x H (mm) 440 x 325 x 86.5 [2U] 600 x 440 x 86.5 [2U]
Net Weight (kgs) 12
19 29.3
External
Battery Model
Dimension, D x W x H (mm) 440 x 325 x 86.5 [2U] 600 x 440 x 86.5 [2U]
Net Weight (kgs) 5.6
10.5 11
ENVIRONMENT
Humidity / Altitude / Temperature 0~95% RH (Non-condensing) / 1500M / Operating 0~50°C & Storage -15°C~60°C
Noise Level Less than 50dB @ 1 Meter
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1; Conformity to IEC / EN
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
MANAGEMENT
Smart RS-232 / USB / IoT Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC, IoT enable
Optional SNMP Power management from SNMP manager and web browser
Technical Specifications of Battery Pack
MODEL BPMPI6N9 BPMPI12N9 BPMPI18N9
Supported UPS 1kVA/2kVA/3kVA
Battery Type 12V-7/9Ah
Battery Number 6 numbers 12 numbers 18 numbers
Battery Voltage 36/72VDC 36/72VDC 36/72VDC
Dimension(DxWxH) 410x438x88 [2U] 630x438x133 [2U] 630x438x133 [3U]
Net Weight (kgs) 22 41 65