MF Series 1~10kVA

A high-performance True Online Double Conversion UPS with advanced PWM technology, delivering stable pure sine wave output and reliable CVCF operation. Equipped with a fully digitized microprocessor, high input power factor (>0.99), and wide input voltage range for maximum efficiency. Features include static bypass, cold start, advanced battery management, and compatibility with Lithium-ion batteries, generators, and solar systems.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online, Double Conversion & PWM Technology.
  • Fully Digitized Microprocessor Control,
  • High Frequency & Pure Sine Wave Output.
  • CVCF (Constant Voltage Constant Frequency)
  • LC Display and Wide Input Voltage Range
  • High Input Power Factor >0.99
  • Static Bypass and Cold Start
  • IGBT Based - Inverter & Rectifier
  • Isolation Transformer Compatible
  • Advanced Battery Management
  • Lithium-ion Battery Compatible
  • EMI/RFI and Noise Filter
  • Generator and Solar Compatible
MODEL MF1101L3 MF1102L4 MF1102 MF1102L8 MF1103L6 MF1103L8 MF1105L16 MF1106L16 MF1110L16
Capacity 1 kVA 2 kVA 3 kVA 5 kVA 6 kVA 10 kVA
INPUT
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 110V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
OUTPUT
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) ≤1%
Crest Factor 3:1
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
DC Voltage 36V 48V 72V 96V 72V 96V 192-240V Configurable
Charge Current 6.5 A Configurable
Typical Recharge Time 4-5 Hours (90% of full capacity)
SYSTEM FEATURES
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation
Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise ≤ 45dBA
PHYSICAL
Dimension WxDxH (mm) 144x400x215 192x469x399 220x481x438
Weight (Kg) 5.6 10.7 10.8 11.2 10.8 11.2 17 18 20
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / UPSilon 2000