MF Series 6kVA

A true online double-conversion UPS with DSP-controlled design, delivering pure sine wave output via IGBT-based rectifier and inverter. Features wide input voltage (110–300V) and frequency range, high input power factor (≥0.99) with low harmonics (≤3%), and unity output power factor. Optimized for long battery life with CVCF charging and supports 192V/216V/240V battery configurations.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
  • True Online Double Conversion Topology
  • DSP Controlled Design
  • Pure Sine wave output waveform
  • IGBT based both Rectifier & Inverter
  • Wide Input Voltage Range (110V -300V AC)
  • High Input Power Factor (≥0.99)
  • Input Current Harmonic ≤ 3%
  • Wide Input Frequency Range
  • High Output Power Factor (Unity, kVA=kW)
  • Optimization Battery Group (192V/216V/240V DC)
  • CVCF Based Charging for long battery life
  • ECO mode for energy saving
  • Self-Testing while UPS Startup
  • Common Battery Bank Operation
  • Static Bypass and Integrated Maintenance Bypass
  • Auto Restart and Cold start function
  • Optional Parallel Compatibility up to 4 units
  • Inbuilt Surge Protection
  • Generator Compatibility

MODEL MF1106L16  
Capacity 6 kVA
INPUT
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 110V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
OUTPUT
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) ≤1%
Crest Factor 3:1
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
DC Voltage 192-240V Configurable
Charge Current 6.5 A Configurable
Typical Recharge Time 4-5 Hours (90% of full capacity)
SYSTEM FEATURES
LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature, Operation
Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise <55dBA
PHYSICAL
Dimension WxDxH (mm) 220x481x610
Weight (Kg) 21.5
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / UPSilon 2000
*Conditions apply.