HXi Series 10~40kVA

Adoption of IGBT Inverter & rectifier, saves energy & coupled with an isolation transformer, enhances the reliability and load adaptability. This unique construction for input and output isolation provides the advantage of noise rejection as well as clean and safe neutral line to the load.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online Double Conversion Design
  • Output Isolation Transformer
  • Wide Input Voltage Range
  • User Friendly Digital LC Display
  • Cold Start Function
  • High Crest Factor Circuit Design
  • Advance Battery Management
  • Improved Input Power Factor
  • Inbuilt High-Rated Charger enable Battery Backup up to 2-10 Hrs.
  • IGBT based charger for smart battery management & improve input powerfactor

Rear Panel


       1. RS232 / SNMP (Optional)
        2. Fan
        3. Input Breaker
        4. Maintenance Bypass Breaker
        5. Input Terminal
        6. Output Terminal
        7. Battery Terminal

Overview:
  • Wide Input Frequency Range ensure all types of fuel generators connected work stable.
  • Optimization of high performance of battery.
  • Advanced floating switching and charging technology maximizes the activation of the battery, thus saves the charging time and extends the battery life.
  • Battery cold start function.
  • The UPS can be start directly by battery group when no utility access in which meets the emergency needs of user.
  • C o m p r e h e n s i v e a n d r e l i a b l e protection
  • self-diagnosis function before startup.
  • The multi-protections such as o ve r l oa d , s h o r t c i rc u i t , o ve r temperature. battery under voltage, battery over voltage and so on greatly ensure the system stability and reliability.
  • Solar compatibility (Optional)
  • Static bypass (Optional)

MODEL HXI3110L16 HXI3110L20 HXI3115L20 HXI3120L20 HXI3115L30 HXI3120L30
Capacity (kVA) 10 15 20 15 20
INPUT
Voltage Range 285V~470V @100% Load, Three Phase (4 Wire)
Frequency Range (Hz) 50Hz ±10%
Power Factor 0.95
OUTPUT
Power Factor 0.8 (Standard) / 0.9 Optional
Voltage (V) 220V/230V/240V ±1% (Configurable)
Frequency (Hz) 50Hz ±0.1%
Waveform Pure Sine Wave
THDv ≤ 2%
Overload ≤ 125% for 10 Min, ≤ 150% for 1 Min, >150% for 300 ms
Efficiency 91.0%
Isolation Transformer Inbuilt Isolation Transformer
BATTERY
Battery Voltage 192V DC 240V DC 360V DC
Charging Current (Max) 1A ~ 10A Standard (High Rating Optional)
Charging Time 4-5 Hrs. to 95%
SYSTEM FEATURES
Display LCD Input and Output Voltage, Input and Output Frequency, Load & Battery %
LED Mains, AC Mode, DC Mode, Low Battery, Overload
Alarm Battery Low Voltage, Abnormal Power Supply, UPS Failure, Overload
Protection Battery Low Voltage, Overload, Short Circuit and Over Temperature
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise ≤63dBA ≤65dBA
STANDARDS
Quality ISO 9000, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
PHYSICAL
Dimension WxDxH (mm) 280x615x685 350x650x795
Weight (Kg) 88 117 150 117 150
COMMUNICATION INTERFACE
Optional SNMP / ModBus / Dry Contact / USB / RS-485 / RS-232
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000