MFP Series 5~10kVA

The UPS features true online double conversion with DSP control, supporting both 50Hz and 60Hz frequencies. It is compatible with generators and includes an ECO mode for energy savings. The system performs self-testing during startup, supports parallel operation of up to four units, and offers static bypass, auto start, and cold start functions.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Features:
  • True Online Double Conversion with DSP
  • Controlled Sine Wave
  • IGBT, Both Inverter & Rectifier
  • Optimization Battery Group, The Quantity of  Battery: 16/18/20 Nos.
  • High Input Power Factor 0.99
  • High Output Power Factor 1.0
  • Wide Input Voltage Range: 120~280V AC
  • Wide Input Frequency Range (50Hz:45~55Hz/60Hz: 54~66Hz)
  • Generator Compatibility
  • Support Economic Operation (ECO) Mode
  • Self-Testing while UPS Startup
  • Optional Parallel upto 4 units
  • Static Bypass and Cold Start
  • Auto Start and cold start function
  • Isolation Transformer Compatible
Overview:

Rear Panel

1. Fan
2. Input Switch
3. Output Switch
4. Maintenance Switch
5. Terminal
6. Com Port
7. USB Port
8. Parallel Port
9. EPO
10. Intelligent Slot / SNMP(Optional)

MODEL MFP1105L16 MFP1106L16 MFP1110L16
Capacity (kVA / kW) 05 / 05 06 / 06 10 / 10
INPUT
Nominal Voltage 220V / 230V / 240V AC (L+N+PE)
Operating Voltage Range 110V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor 0.99
Bypass Voltage ± 20% (Configurable)
Frequency ± 10% (Configurable)
ECO Range Same as the Bypass, can be configured
Generator Input Compatible
OUTPUT
Rated Voltage 220V / 230V / 240V AC L+N+PE (Configurable)
Power Factor 0.8 (Standard) 0.9 / 1.0 (Optional)
Voltage Regulation ±1%
Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Crest Factor 3:1
Overload ≤ 125% for 10 Min, ≤ 150% for 30 Sec, ≥ 150% for 200ms
Harmonic Distortion (THDv) ≤1
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
Battery Voltage 192V DC / 216V & 240V DC (Configurable)
Typical Recharge Time 4-5 Hours to 90% of full Capacity
Charge Current 6A 10A
SYSTEM FEATURES
IP Protection IP 20
Transfer Time Zero
EPO / ECO / CVCF Shutdown UPS Immediately / ECO and CVCF Mode can be Configurable
Alarm / Protection Short Circuit, Input Under/Over Voltage, Over Temperature, Over Current,
Over Load, DC BUS Under / Over Voltage and Battery low
LED Display Line Mode, Backup Mode, ECO Mode, Bypass Mode, Battery Low, Overload & UPS Fault
LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery
Voltage, Temperature & Remaining Battery Backup Time, Load VA/W, Load and Battery Bargraph
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15°C ~ 60°C
Humidity / Altitude 0~95% RH Non-condensing / <1500 M
Noise ≤ 45dBA
PHYSICAL
Dimension WxDxH (mm) 192x465x345 192x540x345
Net Weight (Kg) 12 (L), 58 (B) 14 (L), 68(B)
STANDARDS
Quality ISO 9000, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000