HXi Series 10-40kVA

Adoption of IGBT Inverter & rectifier, saves energy & coupled with an isolation transformer, enhances the reliability and load adaptability. This unique construction for input and output isolation provides the advantage of noise rejection as well as clean and safe neutral line to the load.

Submit Your Enquiry & Our Experts Will Assist You

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
‍Features:
  • True Online Double Conversion Design
  • Output Isolation Transformer
  • Wide Input Voltage Range
  • User Friendly Digital LC Display
  • Cold Start Function
  • High Crest Factor Circuit Design
  • Advance Battery Management
  • Improved Input Power Factor
  • Inbuilt High-Rated Charger enable Battery Backup up to 2-10 Hrs.
  • IGBT based charger for smart battery management & improve input powerfactor

‍

Overview:
  • Wide Input Frequency Range ensure all types of fuel generators connected work stable.
  • Optimization of high performance of battery.
  • Advanced floating switching and charging technology maximizes the activation of the battery, thus saves the charging time and extends the battery life.
  • Battery cold start function.
  • The UPS can be start directly by battery group when no utility access in which meets the emergency needs of user.
  • C o m p r e h e n s i v e a n d r e l i a b l e protection
  • self-diagnosis function before startup.
  • The multi-protections such as o ve r l oa d , s h o r t c i rc u i t , o ve r temperature. battery under voltage, battery over voltage and so on greatly ensure the system stability and reliability.
  • Solar compatibility (Optional)
  • Static bypass (Optional)

‍

‍

‍

MODEL HXi310L16 HXi310L20 HXi315L20 HXi320L20 HXi315L30 HXi320L30 HXi330L30 HXi340L30
Capacity (kVA) 10 10 15 20 15 20 30 40
INPUT
Voltage Range 285V – 470V @100% Load, Three Phase (4 Wire)
Frequency Range 50 Hz ±10%
Power Factor 0.95
OUTPUT
Power Factor 0.8 (Standard) / 0.9 Optional
Voltage 220V / 230V / 240V ±1% (Configurable)
Frequency 50 Hz ±0.1%
Waveform Pure Sine Wave
THDv ≤1%
Overload ≤125% for 10 min, ≤150% for 1 min, ≥150% for 300 ms
Efficiency 94.0%
Isolation Transformer Inbuilt Isolation Transformer
BATTERY
Battery Voltage 192V DC 240V DC 360V DC
Charging Current (Max) 1A – 10A Standard (High Rating Optional)
Charging Time 4–5 Hrs. to 95%
SYSTEM FEATURES
Display (LCD) Input and Output Voltage, Input and Output Frequency, Load & Battery %
Display (LED) Mains, AC Mode, DC Mode, Low Battery, Overload
Alarm Battery Low Voltage, Abnormal Power Supply, UPS Failure, Overload
Protection Battery Low Voltage, Overload, Short Circuit and Over Temperature
ENVIRONMENTAL
Temperature Operating: 0–50°C, Storage: -15°C to 60°C
Humidity / Altitude 0–95% RH Non-condensing / <1500 m
Noise <50 dBA <55 dBA
PHYSICAL
Dimensions WxDxH (mm) 280 × 615 × 685 350 × 650 × 795 280 × 615 × 685
Weight (Kg) 88 117 150 117 150 185 220
COMMUNICATION INTERFACE
Optional SNMP / ModBus / Dry Contact / USB / RS-485 / RS-232
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000